As default, SAFRAN performed dose calculations for releases inside incorporates the IAEA Safety Series No. 115 values of committed effective dose per unit intake via inhalation e(g)inh (Sv/Bq) for workers.
Dose values are taken from the Table II-III following the lung absorption type as per Table II-V for compounds identified as “All compounds” or “All unspecified compounds” and more conservative value for 1 µm or 5 µm AMAD. Otherwise (i.e. when the lung absorption type is specified differently) the most conservative e(g)inh value is used.