Screening dose rate for accidents
The SAFRAN database included screening dose rate value (0.1 mSv/h) for accidental releases inside facility assumes the following exposure conditions:
- the effective dose to worker from release of any considered radionuclide is 0.1 mSv;
- the worker exposure duration is 1 hour.